Behringer B2600 calibration and VCF Modification

Behringer B2600 calibration and VCF Modification

(the pictures are copyright by me - Patrick Joericke, ask me if you want a agreement)

Ā 

Also read the TTSH Calibration guide or ask me for support.

Ā 

Triangle , the original settings from the factory was totally wrong Ā - symmetry(Spike)

Solution:

use a scope and check your waveform andĀ correct this by turning the trimmer TRI Symmetry

Ā 

Thats not a Sine waveĀ !- wrong settings from factory

Solution:

Ā  Ā 

Purity - bends the TRI to a Sine wave - after this check the voltage to 10VPP (adjust the gain)

Ā Ā 

Ā 

Ā 

Filter Frequency, the Filter closed at 100hz instead of less 10hz

Solution:

Move 1 VCO to top in the VCF mixer and try to close the Filter, the signal must stop at 10-20hzĀ Initial Frequency settings., not by 100hz or more, just turn the Trimmer as shown on bottomĀ picture. (read the TTSHĀ calibration guide too, to understand what you do)

Ā 

VCF Modification

Ā 

Ā 

Modded VCF with 1% premium LCR caps in the 4012 and matched 2.5% to 1% tolerance in the 4072 VCF.

I used sockets to make the LCR cap footprint compatible with the PCB RM5 footprint.

Ā 