Behringer B2600 calibration and VCF Modification
(the pictures are copyright by me - Patrick Joericke, ask me if you want a agreement)
Ā
Also read the TTSH Calibration guide or ask me for support.
Ā
Triangle , the original settings from the factory was totally wrong Ā - symmetry(Spike)
Solution:
use a scope and check your waveform andĀ correct this by turning the trimmer TRI Symmetry
Ā
Thats not a Sine waveĀ !- wrong settings from factory
Solution:
Ā Ā
Purity - bends the TRI to a Sine wave - after this check the voltage to 10VPP (adjust the gain)
Ā Ā
Ā
Ā
Filter Frequency, the Filter closed at 100hz instead of less 10hz
Solution:
Move 1 VCO to top in the VCF mixer and try to close the Filter, the signal must stop at 10-20hzĀ Initial Frequency settings., not by 100hz or more, just turn the Trimmer as shown on bottomĀ picture. (read the TTSHĀ calibration guide too, to understand what you do)
Ā
VCF Modification
Ā
Ā
Modded VCF with 1% premium LCR caps in the 4012 and matched 2.5% to 1% tolerance in the 4072 VCF.
I used sockets to make the LCR cap footprint compatible with the PCB RM5 footprint.
Ā
Ā
Ā
Ā
Ā
Related content
how to bugfix: https://diysynth.wiki.dsl-man.de/wiki/spaces/SKM/pages/336101402/How+to+bugfix
non commercial pages, all infos are best can do without warranty, without liability.